Standard dimmable electronicballasts for fluorescent lamps
FL 2x35/220-240V T5 DIM-A
Dimming range from 1-100%
Lamp start at 1% possible
Standard DC1-10V control interface
(EN60929 with earth leakage 0.5mA)
Defined Lamp friendly warm start within
1.5 s with AC and 0.6s with DC
DC operation in emergency lighting
installations to VDE0108
Safe shutdown of defective lamps
Safe shutdown of lamps at end of life
Automatic restart after lamp replacement
Operating frequency ~40-120kHz
FL 2x54/220-240V T5 DIM-A FL 2x36/220-240V T8 DIM-A (Universal voltage dimmable eletronic ballasts for fluorescent lamps)
Dimming range from 1-100%
Lamp start at 1% possible
Standard DC1-10V control interface
(EN60929 with earth leakage 0.5mA)
Defined Lamp friendly warm start within
1.5 s with AC and 0.6s with DC
DC operation in emergency lighting
installations to VDE0108
Safe shutdown of defective lamps
Safe shutdown of lamps at end of life
Automatic restart after lamp replacement
Operating frequency ~40-120kHz
Dimming range from 1-100%
Lamp start at 1% possible
Standard DC1-10V control interface
(EN60929 with earth leakage 0.5mA)
Defined Lamp friendly warm start within
1.5 s with AC and 0.6s with DC
DC operation in emergency lighting
installations to VDE0108
Safe shutdown of defective lamps
Safe shutdown of lamps at end of life
Automatic restart after lamp replacement
Operating frequency ~40-120kHz
FL 1x36/220-240V T8 DIM-A
Dimming range from 1-100%
Lamp start at 1% possible
Standard DC1-10V control interface
(EN60929 with earth leakage 0.5mA)
Defined Lamp friendly warm start within
1.5 s with AC and 0.6s with DC
DC operation in emergency lighting
installations to VDE0108
Safe shutdown of defective lamps
Safe shutdown of lamps at end of life
Automatic restart after lamp replacement
Operating frequency ~40-120kHz
FL 1x42/220-240V TCT DIM-A
Dimming range from 3-100%
Lamp start at 3% possible
Standard DC1-10V control interface
(EN60929 with earth leakage 0.5mA)
Defined Lamp friendly warm start within
1.5 s with AC and 0.6s with DC
DC operation in emergency lighting
installations to VDE0108
Safe shutdown of defective lamps
Safe shutdown of lamps at end of life
Automatic restart after lamp replacement
Operating frequency ~40-120kHz